Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 70A AC/DC |
6,372 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 70A | 1 | Ratiometric, Voltage | - | DC ~ 150kHz | ±1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 600A AC/DC |
8,694 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 36A AC/DC |
2,628 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 36A AC/DC |
4,536 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
4,428 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
2,448 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
7,776 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
6,282 |
|
CSN | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 75A AC/DC |
5,400 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 39.4mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 325A AC/DC |
6,750 |
|
CSLA | AC/DC | Hall Effect, Open Loop | 325A | 1 | Ratiometric, Voltage | 9.1mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | Bidirectional | Through Hole | Module, Single Pass Through | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT SWITCH 5A AC/DC |
2,754 |
|
CSD | AC/DC | Current Switch | 5A | 1 | NPN | - | - | - | - | 4.5V ~ 24V | 100µs | 22mA | -25°C ~ 85°C | Bidirectional | Through Hole | 5-DIP Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT SWITCH 10A AC/DC |
3,600 |
|
CSD | AC/DC | Current Switch | 10A | 1 | NPN | - | - | - | - | 4.5V ~ 24V | 100µs | 22mA | -25°C ~ 85°C | Bidirectional | Through Hole | 5-DIP Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 600A AC/DC |
8,172 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 500A AC/DC |
2,214 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 50A AC/DC |
3,888 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 400A AC/DC |
3,726 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 300A AC/DC |
5,058 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 200A AC/DC |
6,822 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL 100A AC/DC |
6,912 |
|
CSCA-A | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | 15V | 3µs | 17mA | -10°C ~ 80°C | Bidirectional | Chassis Mount | Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL |
6,264 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
Honeywell Sensing and Productivity Solutions |
SENSOR CURRENT HALL |
3,526 |
|
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
Honeywell Sensing and Productivity Solutions |
CURRENT SENSOR |
7,326 |
|
CSN | AC/DC | Magnetoresistive, Open Loop | 8A, 12A, 25A (Selectable) | 3 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 0.2µs | 12mA | -40°C ~ 85°C | Bidirectional | Through Hole | 8-DIP Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
CURRENT SENSOR |
8,154 |
|
CSN | AC/DC | Magnetoresistive, Open Loop | 8A, 12A, 25A (Selectable) | 3 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 0.2µs | 12mA | -40°C ~ 85°C | Bidirectional | Through Hole | 8-DIP Module | - |
|
|
Honeywell Sensing and Productivity Solutions |
CURRENT SENSOR |
3,276 |
|
CSN | AC/DC | Magnetoresistive, Open Loop | 8A, 12A, 25A (Selectable) | 3 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 0.2µs | 12mA | -40°C ~ 85°C | Bidirectional | Through Hole | 8-DIP Module | - |